If you are not able to troubleshoot the problems yourself, you can take the help of a professional or electrician. We hope this Reliance transfer switch troubleshooting guide helps you to fix the common issues. Dewalt Table Saw Troubleshooting Final Words Then, turn off the circuit and unplug the unit from the shore pedestal and correct the input wiring.Ĥ. If the switch's terminals are wired incorrectly, it has a protective feature to prevent the switch from engaging the contactor under a reverse polarity condition. Unit does not engage shore contactor when shore power is present after 3 to 4 secondsĬheck the wiring from the pedestal to the input terminals of the transfer switch.
#THE HOME PROTECTOR SYSTEM BY RELIANCE MANUAL GENERATOR#
The engine cool-down period is typically programmed to be between 10 to 30 minutes at which time the generator will shut down and be ready for another utility outage. To avoid this issue, it's better to continue to run the generator after the load has been transferred back to utility power to allow the engine temperatures to settle back to normal levels. In the engine cool-down period, this situation may occur. Generator Continues to Operate after Transfer Back to utility Power If it is opened, you need to restart the service disconnect breaker or wait until the voltage reaches the acceptable levels. So, you have to check whether it is open or not. If your transfer switch fails to transfer to the utility, it may due to the service disconnect breaker is open or the voltage is unacceptable. OEM and Reliable Reliance Controls Parts at PartsXP Failure to Transfer to Utility Also, caused for fail during maintenance or through the buildup of dirt and grime within the generator. Sometimes solenoids will run too fast that results in heat buildup on it. If the repairing or reprogramming is done and still facing a problem, you need to replace the controller. Suspect the cause for this bad controller and repair or reprogram it. However, a bad controller can't send the correct signals to your generator when you are not having power. Generally, a controller sends an appropriate signal to the generator when there is power shortage. When you connect these wires wrongly or wires got damage, they will not make these wires connection. When power is interrupted in your work area, there is a relay that is held open by utility power closes, allowing these two wires to come together and cause the generator to start. Damaged WiresĪutomatic transfer switch controllers use a standard two-wire start system. Low Prices on Reliance Controls Products - Shop Here.
#THE HOME PROTECTOR SYSTEM BY RELIANCE MANUAL MANUAL#
You can refer to the manual to fix transient voltage issues. The best way to protect a transfer switch from transient voltage hazards or problems is to ensure the proper functioning of the TVSP (transient voltage surge protector). As the voltage flows into the circuit board, it may cause damage to the control boards that will prevent the correct operation. In an automatic transfer switch, the transient voltage affects the sensitive components. If you are unable to do, you can take the help of an electrician. It is the most common problem and also one of the first things that you should check before examining other problems of a transfer switch. Power surges can trip the circuit breaker that provides power to the transfer switch. Order Online Reliance Controls Transfer Switch Kit Tripped Circuit Breakers
#THE HOME PROTECTOR SYSTEM BY RELIANCE MANUAL HOW TO#
Check out details on how to troubleshoot your Reliance transfer switch. This switch helps you by saving generator energy and cuts down a lot of work. The transfer switch lets the inboard generator run as long as there is no supply of power. Reliance Controls Transfer Switch Troubleshooting Guide Unit does not engage shore contactor when shore power is present after 3 to 4 seconds.ġ1. Generator Continues to Operate after Transfer Back to utility Power.ĩ. Reliance Controls Transfer Switch Troubleshooting Guide.Ĩ.